document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Slide it around the pool timer dial to the correct start time and re-tighten it. My timer doesnt seem to be working or my pump in either speed. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. VIDEO TOUR. Pools are not cheap! Any advice on how to fix. the timer was directly plugged into a gfci and the pump directly into the timer. I have an intermatic timer thats 2 years young. Should it still not work, I suspect a motor failure for the clock. Clock wont move, gear dont move at all. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. After a power failure the timer clock can start up backwards, mine has done this several times. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. "@type": "ImageObject",
I am having the same problem. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. With the breakers turned off, remove the mechanism from the box. Switch the breaker off at the power board. It could be a worn switch and/or tripper on the timeclock, struggling to switch it to on, which creates enough overload to trip the breaker. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Tighten them with a wrench. Today is the second day that I have had to turn it on manually. You off course will want to adjust one time pin at a time. Look to see if the clock is set to the correct time. Then after a bit, the pump restarts. I guess if they look the same as before maybe the dial is warped? I have the PF1202T timer on my pool. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. View more property details, sales history and Zestimate data on Zillow. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. Is there a separate switch somewhere between breaker and timer? Elite. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. Just turn the timer wheel until the correct time of the day is aligned with the timer marker that is mounted in front of the wheel. Close. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. "image": {
Ft. 750 Joshua Dr, Hollister, CA 95023. A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. The A terminal is not normally used, unless you have a 3 wire service. 3. Is it Necessary? Dont know what the issue is. The problem is the 'off' tripper. Death By Audio / Levitation Speed Tripper Feedback Phasing Delay I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. Just installed a new timer. My intermatic timer is not turning my pool pump on. For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. The gears in mechanical timers can get damaged. My original timer worked for 5 years then the clock stopped and I heard no sound. "url": "https://blog.intheswim.com/"
"name": "In The Swim",
If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. "@type": "ImageObject",
Just above the yellow clock youll see some holes. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. Tighten down all brass screws securely, to hold all wires firmly in place. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . The 10 Best Pool Timers - Pool Care Guy You can replace the timer motor only, or the entire clock, both fairly easy to swap out. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. Hi Jere, that could be the timer motor failing. Can breaker be bad? Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. DEWENWILS Outdoor Outlet Box. the ground wire? We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. HELP! I noticed one thing that the power from the breaker is going into the control panel. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. Paul, it could be that you got a 50hz motor, instead of a 60hz? "address": "",
I have an intermatic T20004R and my timer is working because it is keeping the correct time. First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. Pull the timer out and turn it to the correct time. The capacitor for the motor may be bad. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. The terminals on the wires aren't tight. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. "caption": "In The Swim Blog"
Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. The power should run from the breaker, to the timer, to the pump. Date Listed: 18/02/2023; . Intermatic T100 Series Replacement Trippers for Timers 156T1978A - The With this model can I control both of these motors with two different on and off times. I have a T104. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. PDF Model: PF1103T TIME CONTROL WITH FREEZE PROTECTION - Heritage Pools, LLC Hi, then the power for the clock must be from the switch, and not from the breaker? I went to the control panel and saw that the timer needle stopped just after the start pointer. Hello Davy, Terry here again. Start with the easy checks. Pop-in a new timer mechanism, and replace the wires to the previous configuration. Your timer is on a 24-hour cycle. Hi Rhomell, are you sure you got the correct trippers? Timer must be reset for current time after power outage. ft. home is a 3 bed, 4.0 bath property. "caption": "In The Swim Blog"
If I manually push the lever, it moves without much pressure. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. I replaced the pump and still nothing is moving. In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Does this mean I need a new T104, or is there a replacement manual on/off switch? I have a Model T104P and have a new green on tripper attached. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? I not sure if this is the best timer to use. I took the electrical box cover off and check the breaker connections. However, the timer will stop around 10pm everyday and will not continue moving forward again. Hi there, But of the timer itself is bad you will need a licensed electrician to change the timer for you. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. They are little ants that just came. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. {
Power surges could be to blame. Put them back on and tighten them. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. The clock is powered from the Line 1 terminal correct? Other than a couple of weeks, we have spent fifteen years manually turning on our pump. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. Not sure if i need to check out the wiring, but it is a bit frustrating. I have a white, red, and black wire coming from the power source. Many thanks! Is the dial bent or warped? "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. Hi Sandra, does the on/off tab switch crisply, or softly? . Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. The 2,810 sq. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. Thank you so much. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . Why it always stop around 10pm by itself and not moving again? It may or may not reduce the noise level however. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. Does the motor gradually start running slowly? I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. Pool Timer Clock Parts and Trippers Perhaps bad wiring or a bad breaker is to blame. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. My Polaris booster pump ONLY turns on via the trippers. However the new breaker is in a constantly tripped position. They should be straight, if not, replace them. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. Stupid third question, but does the ON tripper say ON? Look for any disconnected or damaged wires leading to the motor on the rear of the clock. Reset the clock on the timer to the correct time to get it back to the desired on/off times. Terminal A (farthest to the left side) is not connected to anything. I need to replace a timer for my pool vacuum. My intermatic timer is about two years old as well. I looked through the visual motor check and the gear still moving fine. Is it Necessary? Any suggestions? It is a mechanical issue between the trippers and the switch lever. Voltage is 243, frequency is 60hz. Jul 20, 2021. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. Hi, new timer out of the box, 200V. Check that the TEST button has not popped out. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. How about the GFCI outlet TEST button, is it tripped? It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. It worked for a day but the day after it didnt work. When you flip the switch does it separate and reconnect the tabs? "datePublished": "1/10/2020",
Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. It is still moving and it will trip off but not on. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. 7 Best Pool Pump Timers (Winter 2023) - Reviews & Buying Guide The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. I replaced the fuse(BUSS 300v GLR 3) as well. screwfindinganame on June 18, 2013 at 11:36 pm Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. PF1202T Freeze Protection Control Parts - INYOPools.com Check that dial is not warped. Basically youre eliminating possibilities until you find the cause. Inspect the tripper portion, if it looks rounder or worn, replace them. Posted by 4 years ago. Hey there! Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . First you want to make sure there is actually power getting from the power board to the timer itself. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. Is there anything else I can do or do I need to get a new one? "@context": "https://schema.org/",
Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. "height": "219",
You can find this in your power board. Back when I was a young technician I was taught to always look for the easy things and use all my senses. The time does not advance after resetting. A power surge may have taken out the timer or the pump. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. If you dont have the voltage here you have an issue with either the wiring or the breaker. Proceed to step 4 to check the timer itself. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? It should be 110V or 220V AC. There is a second switch between the breaker and the timer. More. Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. Then remove the mechanism by pressing the clip at the top of the timer box. Now, Im going to order some additional timer clips. Could also be grit or insects inside of the gears of the clock motor. PDF Model: T104 24 Hour Dial Time Switch I can, however, hear an intermittent click as if the mechanism is trying to switch on. To do this, pull the yellow-faced time dial (clockface) toward you. THE 10 CLOSEST Hotels to Time Tripper - tripadvisor.ca Check out our online selection of new Intermatic timer clocks at InTheSwim.com! Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. Pool timer malfunction - DoItYourself.com Community Forums please help me. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. Ordered new ones. I think I have found it. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. Yes, seen that before! The on/off pins are tight and pretty new stillany thoughts? Read Book Tork Trippers Manual Guide Pdf For Free - twiki.skotos My pump has a plug. Timer not tripping pump on. I have a PF1112T. Now it worksbut its really fast. Sometimes the trippers get loose or damaged.